The ohm is a unit of electrical resistance. One volt will cause a current of one ampere to flow through a resistance of one ohm.
歐姆
歐姆是電阻單位。1伏特的電壓通過1歐姆的電阻能產生1安培的電流。
One-Line Diagram
A one-line diagram is a schematic diagram of a three-phase power distribution system which uses one line to show all three phases. It is understood when using this easy to read drawing that one line represents three.
單線圖
單線圖是用一條線來表示三相電力分布系統的示意。,
Overcrank
Overcrank is an alarm function provided with most generator sets that indicate that the generator set has failed to start.
盤車失敗
盤車失敗是機組的預警功能,表示發電機組啟動失敗,大多數機組都有這種功能。
Overshoot
Overshoot refers to the amount by which voltage or frequency exceeds the nominal value as the voltage regulator or governor responds to changes in load
超調
超調是指電壓調節器或控制器響應負載的變化時,導致電壓或頻率超出正常值的那部分。
P
Paralleling Breaker
A paralleling breaker is the circuit breaker that connects the generator set to the emergency bus, and across which all the individual generator synchronizing functions occur.
并聯開關
并聯開關是連接發電機組和應急母排的線路斷路器,所有的單個發電機通過它完成同步運行。
Paralleling Control
A paralleling control contains the electrical equipment provided in a paralleling system for control of a single generator set.
并聯控制
并聯控制是并聯系統中用來控制單個發電機組的電氣設備。
Peak Load
Peak load is the highest point in the kilowatt demand curve of a facility. This is used as the basis for the utility company's demand charge.
峰值功率
峰值功率是用電設備的功率需求曲線中的最大值。
Peer-To-Peer
A network operating system where any device on the main network bus can initiate communication.
點對點
點對點是一種網絡運行系統,任何設施都可以發起信息交換。
Phase Angle
Phase angle refers to the relation between two sine waves which do not pass through zero at the same time. Considering one full cycle to be 360 degrees, the phase angle expresses how far apart the two waves are in relation to each other in degrees.
相角
相角指的是兩個不同時經過零點的正弦波之間的關系。一個完整周期為360度,相角就是用度數來表示兩個波的距離。
Phase Rotation
Phase rotation (or phase sequence) describes the order (A-B-C, R-S-T, or U-V-W) of the phase voltages at the output terminals of a three-phase generator. The generator phase rotation must match the facility phase rotation. This must be checked prior to operation of the electrical loads in a facility with an on-site generator.
相序
相序表示的是三相發電機輸出終端相電壓的順序。在用電負載運轉之前必須檢查確保發電機的相序與用電設施的相序一致。
Port
The external connector on a device at which the network cable or medium is attached.
接口
設備的外接口,用于連接網絡線或者其它介質。
Power Factor
Power factor is the cosine of the angle between the active power (kW) and apparent power (kVA) in a circuit.
功率因數
功率因數是電路中有功功率(kW)和視在功率(kVA)之間夾角的余弦值。
Prime Power
Prime Power describes an application where the generator set(s) must supply power on a continuous basis and for long periods of time between shutdowns. No utility service is present in typical prime power applications.
常載
常載是指發電機組可長時間和連續的運行。通常在沒有市電供應,發電機組作為首要電源的場合使用。
Priority Control
Priority control is the process by which the total loads on the bus is limited to the most critical loads in the system until adequate generation capacity is available to serve all loads.
優先級控制
優先級控制是指當總負載電力需求大于發電機組的輸出時,首先要滿足最關鍵負載的電力需求。
Protocol
A set of rules used mutually by two or more devices to communicate. Also, known as the "language" used in a network.
協議
兩個或多個設施共同遵守的一些通訊規則,在網絡中常稱為“語言”。
R
Radio Interference
Radio interference refers to the interference with radio reception caused by a generator set.
無線電干擾
無線電干擾是指發電機組對無線電信號接收造成的干擾。
Reactive Power
Reactive power is power that flows back and forth between the inductive windings of the generator and the inductive windings of motors, transformers, etc., which are part of the electrical load. This power does no useful work in the electrical load nor does it present load to the engine. It does apply load to the generator and limits the capacity of the generator.
無功功率
無功功率是指電流在發電機、電動機、變壓器等的感應線圈之間往復流動,這也構成了電力負載的一部分。它并沒做有用功,而且也不是發動機的負載,但是作為發電機負載,限制了發電機的容量。
Reverse Power Relay
A reverse power relay is a relay with a wattmeter movement that senses the direction of power flow. In paralleled sets, a flow of reverse power (i.e., power flow into set) will actuate the reverse power relay and disconnect the set from the system. If one set stops and reverse power protection is not provided, the set still running will drive the set that has stopped. The generator on the set that has stopped will act as a motor.
逆功率繼電器
逆功率繼電器是指帶瓦特計的繼電器,用來感知電流的方向。在并聯機組中,反方向電流(例如流回發電機組的電流)會啟動逆功率繼電器,把該機組與系統斷開。如果一臺發電機組沒有運轉,并且沒有逆功率繼電器保護,運轉的機組就會驅動這個機組,這臺機組上的發電機則變成電動機運行。
Router
A device for passing network messages over another media and sometimes protocol. Our network router is programmed as a "repeater" to create another channel on the main network bus. Each channel can have a 4,600 ft. network bus and is capable of having 44 nodes. The PowerCommand Network can have up to twenty (20) channels.
路由器
路由器是把網絡信息通過另外一種介質(有時是協議)傳送出去的裝置。我們的網絡路由器被設定為“轉發器”,在主網絡上創建另外一個信道。每個信道有4,600 ft網絡母排,可容納44個接點。 PowerCommand 網絡最多可有20個信道。
S
SCR
Silicon Controlled Rectifier -- a three-electrode solid-state device which permits current to flow in one direction only, and does this only when a suitable potential is applied to the third electrode, called the gate.
可控硅整流器
可控硅整流器——三電極固態元件,只有當匹配的電壓作用于第三電極(選通電極)時,才能夠保證電流朝一個方向流動。
Short Circuit
A short circuit is generally an unintended electrical connection between current carrying parts.
短路
短路通常是指帶電流的組件之間意外的電路連接。
Shunt Trip
Shunt trip is a feature added to a circuit breaker or fusible switch to permit the remote opening of the breaker or switch by an electrical signal.
分勵脫扣
分勵脫扣是線路斷路器或可熔電閘的一個特性,可通過遠程信號來進行分斷或轉換。
Soft Loading
Soft loading refers to the ramping of load onto or off of a generator in a gradual fashion for the purpose of minimizing voltage and frequency transients on the system.
軟加載
軟加載是指在給發電機組增加或減少負載時要逐漸進行,以減少電壓和頻率對系統的瞬變影響。
Sound Level Meter
A sound level meter measures sound pressure level. It has several frequency-weighted decibel (dB) scales (A, B, C) to cover different portions of the range of measured loudness. Sound level meters indicate RMS sound, unless the measurements are qualified as instantaneous or peak sound level.
聲級表
聲級表是用來測量聲壓級別的,它根據聲音的頻率分為幾個分貝級(A, B, C)。聲級表表征的是均方根聲音,除非是適合瞬間或峰值的度量。
Sound Pressure Level (SPL)
Sound pressure level is a measurement of the pressure fluctuations of a sound wave as it propagates through the air. Because of the wide range of pressures to which the ear responds, a logarithmic scale is used and is expressed as a ratio of the measured pressure referenced to a pressure of 2x10-5 N/m2 (20 m Pa) which is the threshold of human hearing at 1000 Hz. The measure is expressed in decibels (dB). The Bel unit is named after Alexander Graham Bell.
聲壓級別
聲壓級別是表示在空氣中傳播的聲波的起伏壓。由于耳朵能感知的聲壓范圍很大,所以采用其對數值,并以2x10-5 N/m2 (20 m Pa)的比率表示,這是人類在1000 Hz所能聽到的極限,單位是分貝(dB)。貝爾(十分貝)是以亞歷山大·格雷姆·貝爾的名字命名的。
Standby System
A standby system is an independent power system that allows operation of a facility in the event of normal power failure.
備用系統
備用系統是一個獨立的電力供應系統,當常規電力供應失敗時,備用系統就會運行。
Star Connection
See Wye Connection.
星形連接
參見Y形連接。
Starting Current
The initial value of current drawn by a motor when it is started from standstill.
啟動電流
當發動機從停止狀態啟動時帶來的初始電流值就是啟動電流。
Surge
Surge is the sudden rise in voltage in a system, usually caused by load disconnect.
突變
突變是指系統中電壓突然升高,通常是由于負載斷開而引起的。
Surge Suppressor
Surge suppressors are devices capable of conducting high transient voltages. They are used for protecting other devices that could be destroyed by the transient voltages.
突變抑制器
突變抑制器是能夠抑制瞬間高電壓的設施,用來保護其他設備免受瞬間電壓的破壞。
Sync Check Relay
A sync check relay is an electrical device that monitors the phase relationship between two voltage sources and provides a signal when the voltage sources are within specific preset parameters.
同步檢查繼電器
同步檢查繼電器是監測兩個電壓源之間的相位關系的電氣設備,如果電壓源間的關系在預定的參數范圍內,它就會發出相應信號。
Synchronizer
A synchronizer is an electronic device that monitors the phase relationship between two voltage sources and provides a connection signal to an engine governor, to force the generator set to synchronize to the system bus.
同步器
同步器是用來監測兩個電壓源之間的相位關系的電子設備,它向發動機調速器發出信號,以促使發電機組與系統母排能夠同步。
Synchronous Generator
A synchronous generator is an AC generator having a DC exciter. Synchronous generators are used as stand-alone generators for emergency power and can also be paralleled with other synchronous generators and the utility system.
同步發電機
同步發動機是配有直流勵磁機的同步交流發電機。同步發動機能作為獨立的緊急電源,也可以與其他同步發電機或市電并聯。
T
Terminator
A resistive load placed at the end of a cable to prevent data signals from reflecting back into the data path.
終結器
終結器就是置于電纜終端的一個電阻負荷,用來防止數據信號又反射回到線路中去。
Transfer Switch
A transfer switch is an electrical device for switching loads between alternate power sources. An automatic transfer switch monitors the condition of the sources and connects the load to the alternate source if the preferred source fails.
轉換開關
轉換開關是能夠把負載在備用電源和常規電源之間進行轉換的電氣設施。自動轉換開關能夠進行監控,如果首選電源供應失敗,就自動把負載連接到備用電源。
- 2019-02-21● 柴油發電機組氣門的常見故障
- 2019-02-19● 柴油發電機的每周保養
- 2019-02-15● 發電機不能瞬間加速的原因
- 2019-02-14● 柴油發電機的油耗問題
- 2019-02-13● 發電機曲軸的工作條件
- 2019-02-12● 柴油發電機怠速太高要檢查哪些部位?
- 隨機推薦
- 2017-03-28● 什么是發電機組逆功率保護及敲缸原因
- 2016-04-07● 珠海發電機:柴油發電機組機油更換
- 2018-09-19● 發電機組如何防腐防污染
- 2016-11-10● 柴油發電機與UPS系統的使用問題
- 2014-08-10● NTA855-G4重慶康明斯發電機組技術參數
- 2014-07-16● 發電機租憑